Title of article
A mixed approach to artifacts minimization in a continuous-rotate X-ray based tomographic imaging system using linear detector array
Author/Authors
Umesh Kumar، نويسنده , , G. S. Ramakrishna، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
13
From page
543
To page
555
Abstract
Adaptation of a general-purpose digital radiographic scintillator-based linear detector array (LDA) in a continuous-rotate third generation X-ray industrial tomographic imaging system and the resulting artifacts are discussed. Sources of error in the projection data are identified and a mixed approach, involving neighborhood averaging and row-wise application of a low-pass filter for the minimization of artifacts in the reconstructed images using weighted convolution back projection algorithm is illustrated. It is observed that the recently launched LDA can easily be adapted for industrial tomographic imaging of low-density specimen in a cost effective way by incorporating the suggested artifact removal technique in the given configuration.
Keywords
Nondestructivetesting , Computed tomography imaging , Linear detector array , Gamma-rays , computed tomography , X-rays , artifacts
Journal title
Applied Radiation and Isotopes
Serial Year
2002
Journal title
Applied Radiation and Isotopes
Record number
541337
Link To Document