Title of article :
Shortening of pulse-width for immediately succeeding trigger signals in the use of logic pulse shapers for nuclear experiments
Author/Authors :
Qiu-Wei Wang، نويسنده , , Yasushi Kawada، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
4
From page :
419
To page :
422
Abstract :
If a second succeeding pulse arrives immediately after a first preceding pulse in the output from a non-retrigerable monostable multivibrator, the width of the succeeding pulse is somewhat shortened. Using a time-to-amplitude converter followed by a multi channel analyzer, the pulse-width shortening of the succeeding pulse was measured as a function of the time interval between the two pulses. It was found that this effect was highly dependent on the resistance of an external RC time constant circuit. Similar measurements were also carried out for nuclear instrument modules involving the monostable multivibrator circuits.
Keywords :
Succeeding pulse , Logic pulse shaper , Time jitter , Coincidence experiments , Monostable multivibrator , Pulse-width shortening