• Title of article

    Standardization of 65Zn by 4πPC-γ coincidence counting method with efficiency extrapolation

  • Author/Authors

    Maria Sahagia، نويسنده , , C. Ivan، نويسنده , , E. L. Grigorescu، نويسنده , , M. Capogni، نويسنده , , P. de Felice، نويسنده , , A. Fazio، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    5
  • From page
    423
  • To page
    427
  • Abstract
    A 65Zn solution was standardized by the 4πPC–γ efficiency-extrapolation coincidence counting method. Theoretical aspects of coincidence equations, efficiency equations and linearity conditions are reviewed. Experimental measurements were performed for two low level discrimination thresholds for the PC channel (counting K+L or K X-rays or Auger electrons from EC decay) and for three different settings of the γ window. Requirements on γ channel set-up for linear extrapolation were established by using a Pb absorber or by proper γ window setting. The measured activity values were discussed and found in good agreement with those obtained with a calibrated ionization chamber.
  • Keywords
    Coincidence-counting method , Efficiency extrapolation , Linearity conditions , Triangular decay scheme , 65Zn
  • Journal title
    Applied Radiation and Isotopes
  • Serial Year
    2004
  • Journal title
    Applied Radiation and Isotopes
  • Record number