Title of article :
Characteristics of BDE dependent on 10B concentration for accelerator-based BNCT using near-threshold 7Li(p,n)7Be direct neutrons
Author/Authors :
K. Tanaka، نويسنده , , T. Kobayashi، نويسنده , , G. Bengua، نويسنده , , Y. Nakagawa، نويسنده , , S. Endo، نويسنده , , M. Hoshi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
5
From page :
875
To page :
879
Abstract :
The characteristics boron-dose enhancer (BDE) was evaluated as to the dependence on the 10B concentration for BNCT using near-threshold 7Li(p,n)7Be direct neutrons. The treatable protocol depth (TPD) was utilized as an evaluation index. MCNP-4B calculations were performed for near-threshold 7Li(p,n)7Be at a proton energy of 1.900 MeV and for a polyethylene BDE. Consequently, the TPD was increased by increasing T/N ratio, i.e., the ratio of the 10B concentration in the tumor (10BTumor) to that in the normal tissue (10BNormal), and by increasing 10BTumor and 10BNormal for constant T/N ratio. It has been found that the BDE becomes unnecessary from the viewpoint of increasing the TPD, when 10BTumor is over a certain level.
Keywords :
BDE , n)7Be , TPD , MCNP , accelerator , 10B concentration , 7Li(p
Journal title :
Applied Radiation and Isotopes
Serial Year :
2004
Journal title :
Applied Radiation and Isotopes
Record number :
541842
Link To Document :
بازگشت