Title of article
Flux and instrumentation upgrade for the epithermal neutron beam facility at Washington State University
Author/Authors
D. W. Nigg، نويسنده , , J. R. Venhuizen، نويسنده , , C. A. Wemple، نويسنده , , G. E. Tripard، نويسنده , , S. Sharp، نويسنده , , K. Fox، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
4
From page
993
To page
996
Abstract
An epithermal neutron beam facility for preclinical neutron capture therapy research has been constructed at the Washington State University TRIGA research reactor installation. Subsequent to a recent upgrade, this new facility offers a high-purity epithermal beam with intensity on the order of 1.2×109 n/cm2 s. Key features include a fluoride-based design for the neutron filtering and moderating components as well as a novel collimator design that allows ease of assembly and disassembly of the beamline components.
Keywords
BNCT , epithermal neutron beam , Preclinical research , boron
Journal title
Applied Radiation and Isotopes
Serial Year
2004
Journal title
Applied Radiation and Isotopes
Record number
541862