Title of article :
Theoretical estimates of the solid angle subtended by a dual diaphragm–detector assembly for alpha sources
Author/Authors :
Julio C. Aguiar، نويسنده , , Eduardo Galiano، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
Knowledge of the solid angle subtended by a detector is essential for the determination of the activity of a radioactive source. This work investigates the influence of diaphragm and source diameter, and source to diaphragm distance, on the solid angle subtended by a dual opposed α diaphragm–detector assembly. Expressions published by Segre, Ruby, and others, and the Monte Carlo method are used. The analytical expressions consistently produced higher estimates than the Monte Carlo method for the solid angle.
Keywords :
Radiation detector , Monte Carlo method , Geometric efficiency , Solid angle
Journal title :
Applied Radiation and Isotopes
Journal title :
Applied Radiation and Isotopes