Title of article :
Simple automated preparation of O-[11C]methyl-l-tyrosine for routine clinical use
Author/Authors :
Yoichi Ishikawa، نويسنده , , Ren Iwata، نويسنده , , Shozo Furumoto، نويسنده , , Claudio Pascali، نويسنده , , Anna Bogni، نويسنده , , Kazuo Kubota، نويسنده , , Kiichi Ishiwata، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
7
From page :
55
To page :
61
Abstract :
The previously reported preparation of O-[11C]methyl-l-tyrosine ([11C]MT), a promising tumor imaging agent, has been now considerably simplified and automated. Main changes were the use of [11C]methyl iodide ([11C]MeI) in the reaction with l-tyrosine disodium and the use of solid phase extraction on commercially available cartridges instead of HPLC for the final purification. An injectable saline solution of [11C]MT was obtained within 30 min after EOB with radiochemical yield of ca. 60% (decay-corrected, based on [11C]MeI). Radiochemical purity was over 97%. The automated preparation was carried out using a miniature module employing manifold valves.
Keywords :
Automated synthesis , C-11 , Amino acid transport , Tumor imaging , O-methyl-l-tyrosine
Journal title :
Applied Radiation and Isotopes
Serial Year :
2005
Journal title :
Applied Radiation and Isotopes
Record number :
542076
Link To Document :
بازگشت