Title of article :
Assessment of bone surrounding implants in goats: ex vivo measurements by dual X-ray absorptiometry
Author/Authors :
F. G. A. Corten، نويسنده , , H. Caulier، نويسنده , , J. P. C. M. van der Waerden، نويسنده , , W. Kalk، نويسنده , , F. H. M. Corstens، نويسنده , , J. A. Jansen، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Abstract :
The aim of the present study is to determine the possibility of measuring the bone mineral density (BMD) around implants by dual energy X-ray absorptiometry (DEXA). Therefore, the trabecular BMD was measured close to 127–600 μm and at a distance from various uncoated and Ca---P-coated implants inserted into the femoral condyle of goats. The implants were left in situ for 12 weeks. In addition, the bone-implant interface was evaluated histologically. For comparative reasons the BMD of non-implanted lateral and medial femoral condyles was also measured.
Keywords :
bone mineral density , trabecular bone , implants , dual photon absorptiometry (X-photon) , Dual energy X-ray absorptiometry (DEXA)
Journal title :
Biomaterials
Journal title :
Biomaterials