• Title of article

    Mixing in Process Vessels Used in Biopharmaceutical Manufacturing

  • Author/Authors

    Slater، Nigel K. H. نويسنده , , Ram، Kripa نويسنده , , Vickroy، T. Bruce نويسنده , , Lamb، Keith A. نويسنده , , Dennis، John S. نويسنده , , Duffy، Louise E. نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2000
  • Pages
    -243
  • From page
    244
  • To page
    0
  • Abstract
    The use of nonbaffled vessels for mixing applications is becoming common in the biopharmaceutical industry but is not sufficiently well studied. Orientation of the impellers off-centered and/or at an angle is necessary to enhance mixing and eliminate swirling that would result without a baffle in a standard tank. This study focuses on characterizing mixing in vessels with the hydrofoil axial flow impellers mounted offcenter at 10° to the vertical. Geometrically similar vessels ranging from 100 to 5000 L working volume were used in this study. Mixing performance was successfully correlated to vessel geometric factors.
  • Keywords
    Interference , lnterruptions , Work activity , Time-sharing
  • Journal title
    BIOTECHNOLOGY PROGRESS
  • Serial Year
    2000
  • Journal title
    BIOTECHNOLOGY PROGRESS
  • Record number

    5447