Title of article :
Platelet adhesion on silicon modified hydrogenated amorphous carbon films
Author/Authors :
T. I. T. Okpalugo، نويسنده , , A. A. Ogwu، نويسنده , , P. D. Maguire، نويسنده , , J. A. D. McLaughlin، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
We have investigated the effect of changes in microstructure, surface energy, surface charge condition and electronic conduction on the interaction of human platelets with silicon modified hydrogenated amorphous carbon films (a-C:H:Si or Si-DLC). Results based on Raman spectroscopy, Scanning electron microscopy, X-ray photo-electron spectroscopy, surface energy measurements, electrical resistivity, contact potential difference, and thermal annealing indicates a correlation between some of the measured values and the interaction of the films with human blood platelets. Statistical analysis of platelet aggregation on the films using the Studentʹs t-test indicated differences between platelet aggregation on the modified films compared to the as-deposited film at a p-value of <0.05.
Keywords :
Si-DLC , Raman spectroscopy , Contact angle/surface energy , Haemocompatibility , Work function/semi-conduction , Human plateletaggregation
Journal title :
Biomaterials
Journal title :
Biomaterials