• Title of article

    Polymerization of the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) around living neural cells

  • Author/Authors

    Sarah M. Richardson-Burns، نويسنده , , Jeffrey L. Hendricks، نويسنده , , Brian Foster، نويسنده , , Laura K. Povlich، نويسنده , , Dong-Hwan Kim، نويسنده , , David C. Martin، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    14
  • From page
    1539
  • To page
    1552
  • Abstract
    In this paper, we describe interactions between neural cells and the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) toward development of electrically conductive biomaterials intended for direct, functional contact with electrically active tissues such as the nervous system, heart, and skeletal muscle. We introduce a process for polymerizing PEDOT around living cells and describe a neural cell-templated conducting polymer coating for microelectrodes and a hybrid conducting polymer-live neural cell electrode. We found that neural cells could be exposed to working concentrations (0.01 m) of the EDOT monomer for as long as 72 h while maintaining 80% cell viability. PEDOT could be electrochemically deposited around neurons cultured on electrodes using 0.5–1 μA/mm2 galvanostatic current. PEDOT polymerized on the electrode and surrounded the cells, covering cell processes. The polymerization was impeded in regions where cells were well adhered to the substrate. The cells could be removed from the PEDOT matrix to generate a neural cell-templated biomimetic conductive substrate with cell-shaped features that were cell attracting. Live cells embedded within the conductive polymer matrix remained viable for at least 120 h following polymerization. Dying cells primarily underwent apoptotic cell death. PEDOT, PEDOT+live neurons, and neuron-templated PEDOT coatings on electrodes significantly enhanced the electrical properties as compared to the bare electrode as indicated by decreased electrical impedance of 1–1.5 orders of magnitude at 0.01–1 kHz and significantly increased charge transfer capacity. PEDOT coatings showed a decrease of the phase angle of the impedance from roughly 80° for the bare electrode to 5–35° at frequencies >0.1 kHz. Equivalent circuit modeling indicated that PEDOT-coated electrodes were best described by R(C(RT)) circuit. We found that an RC parallel circuit must be added to the model for PEDOT+live neuron and neuron-templated PEDOT coatings.
  • Keywords
    electroactive polymer , Interface , electrode , Biomimetic material , Neural prosthesis
  • Journal title
    Biomaterials
  • Serial Year
    2007
  • Journal title
    Biomaterials
  • Record number

    547439