• Title of article

    Validation of alternative methods of preparing 99mTc-MAG3

  • Author/Authors

    Shankar Seetharaman، نويسنده , , Michael H. Sosabowski، نويسنده , , James R. Ballinger، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    4
  • From page
    1240
  • To page
    1243
  • Abstract
    Parameters in the preparation of 99mTc-mertiatide (99mTc-MAG3) were investigated to determine the importance of total activity, activity concentration, boiling time, and delay before boiling for the radiochemical purity (RCP) and stability of the product. Satisfactory RCP results (>90%) were obtained over a range of concentrations including a dilute preparation for paediatric use. RCP was not affected by the time between the addition of pertechnetate and boiling, but low RCP (<60%) resulted when the kit was boiled for less than 10 min.
  • Keywords
    Paediatric dosing , 99mTc-MAG3 , Radiochemical purity , Dynamic renal imaging
  • Journal title
    Applied Radiation and Isotopes
  • Serial Year
    2007
  • Journal title
    Applied Radiation and Isotopes
  • Record number

    548309