Title of article
On the optimization of the isotopic neutron source method for measuring the thermal neutron absorption cross section: Advantages and disadvantages of BF3 and 3He counters
Author/Authors
A. Bolewski Jr، نويسنده , , M. Ciechanowski، نويسنده , , A. Dydejczyk، نويسنده , , A. Kreft، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
6
From page
457
To page
462
Abstract
The effect of the detector characteristics on the performance of an isotopic neutron source device for measuring thermal neutron absorption cross section (Σ) has been examined by means of Monte Carlo simulations. Three specific experimental arrangements, alternately with BF3 counters and 3He counters of the same sizes, have been modelled using the MCNP-4C code. Results of Monte Carlo calculations show that devices with BF3 counters are more sensitive to Σ, but high-pressure 3He counters offer faster assays.
Keywords
3He counter , Thermal neutron absorption , sensitivity , MCNP , BF3 counter