• Title of article

    Electrochemical biosensor based on supported planar lipid bilayers for fast detection of pathogenic bacteria

  • Author/Authors

    Tien، H. T. نويسنده , , Ottova، A. نويسنده , , Wilkins، E. نويسنده , , Ivnitski، D. نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2000
  • Pages
    -456
  • From page
    457
  • To page
    0
  • Abstract
    This paper presents a new ion-channel biosensor based on supported bilayer lipid membrane for direct and fast detection of Campylobacter species. The sensing element of a biosensor is composed of a stainless-steel working electrode, which is covered by artificial bilayer lipid membrane (BLM). Antibodies to bacteria embedded into the BLM are used as channel forming proteins. The biosensor has a strong signal amplification effect, which is defined as the total number of ions transported across the BLM. The total number of (univalent) ions flowing through the channels is 1010 ions s1. The biosensor showed a very good sensitivity and selectivity to Campylobacter species.
  • Keywords
    Dimethylglyoxime , Bismuth electrode , Adsorptive stripping voltammetry , nickel
  • Journal title
    ELECTROCHEMISTRY COMMUNICATIONS
  • Serial Year
    2000
  • Journal title
    ELECTROCHEMISTRY COMMUNICATIONS
  • Record number

    54845