Title of article :
Investigating the background of a 1-cm3 quartz gas proportional counter
Author/Authors :
George A. Klouda، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
5
From page :
860
To page :
864
Abstract :
The background count rate of a 1-cm3 quartz gas proportional counter (GPC) was investigated for measuring natural radioactivity levels of small samples. Using a new multiparameter digital counting system, spurious or afterpulses that contribute to background were identified by their pulse waveform and by a special event indicator defined by the time (<2000 μs) between two successive pulses. With the GPC in coincidence with a low-background NaI(Tl) scintillation guard detector, the weighted mean and standard uncertainty anticoincidence counts per day (d−1) was 6.2±0.4 d−1.
Keywords :
Gas proportional counter , background , Risetime , Afterpulse , Digital acquisition , Low-level decay counting , Pulse waveform , Natural radioactivity
Journal title :
Applied Radiation and Isotopes
Serial Year :
2008
Journal title :
Applied Radiation and Isotopes
Record number :
548463