Title of article
A quantitative and comparative study of radionuclidic and chemical impurities in water samples irradiated in a niobium target with Havar vs. niobium-sputtered Havar as entrance foils
Author/Authors
Miguel A. Avila-Rodriguez، نويسنده , , John S. Wilson، نويسنده , , Steve A. McQuarrie، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
6
From page
1775
To page
1780
Abstract
Enriched and natural abundance water samples were irradiated in a niobium (Nb) chamber target with Havar and Nb-sputtered Havar foils. Irradiations were performed with 17.5 MeV protons at currents from 35 to 100 μA lasting for 1–2.5 h. Radionuclidic and chemical (cationic) impurities were determined via gamma spectroscopy and ICP-MS, respectively. Anionic impurities were evaluated by ion chromatography. Impurities in water samples irradiated with the Havar-Nb foils were much lower than the samples irradiated with an unmodified Havar foil. No significant differences were observed in the impurity levels between samples of H218O-enriched and natural abundance water. Radionuclidic impurities were observed to decrease after 3–4 irradiations on a fresh Havar entrance foil, and reached a constant value for subsequent irradiations with the same integrated current. For targets covered with Havar foil, radionuclidic impurities were found to be proportional to the beam-integrated current regardless of the beam power and, unexpectedly, dependant of the beam power when using a Havar-Nb foil.
Keywords
Niobium-sputtered foils , 18F-fluoride for FDG production , Reactivity of NCA 18F-fluoride , Impurities in 18F-fluoride , Havar foils
Journal title
Applied Radiation and Isotopes
Serial Year
2008