Title of article :
Liquid ventilation in adults, children, and full-term neonates
Author/Authors :
R. B. Hirschl، نويسنده , , T. Pranikoff، نويسنده , , P. Gauger، نويسنده , , R. J. Schreiner، نويسنده , , R. Dechert، نويسنده , , R. H. Bartlett، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1995
Pages :
2
From page :
1201
To page :
1202
Abstract :
We evaluated the safety and efficacy of partial liquid ventilation in a series of 19 adults, children, and neonates who were in respiratory failure and on extracorporeal life support. During partial liquid ventilation, the alveolar-arterial oxygen difference decreased from 590 (SE 25) to 471 (42) mm Hg (p=0·0002) and static pulmonary compliance increased from 0·18 (0·04) to 0·29 (0·04) mL cm H2O-1 kg-1 (p=0·0002). 11 patients (58%) survived. These preliminary data suggest that partial liquid ventilation can be safely used in patients with severe respiratory failure and may improve lung function.
Journal title :
The Lancet
Serial Year :
1995
Journal title :
The Lancet
Record number :
563329