Title of article :
Recurrent hearing loss after myelography treated with epidural blood patch
Author/Authors :
Muneo Nakaya، نويسنده , , Ichiro Morita، نويسنده , , Masatoshi Horiuchi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
Transient hearing impairment is a known sequel after various procedures that result in loss of cerebrospinal fluid, such as lumbar puncture, spinal anesthesia and myelography. But persistent or recurrent hearing loss after dural puncture is a rare entity. We present a case with recurrent low-frequency sensorineural hearing loss after myelography. The patient was treated successfully by means of an epidural blood patch, although the conservative treatment was ineffective.
Keywords :
Hearing loss , myelography , Lumbar puncture , Epidural blood patch
Journal title :
Auris Nasus Larynx
Journal title :