Title of article :
Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II)
Author/Authors :
Patrick W Serruys، نويسنده , , Ben van Hout، نويسنده , , Hans Bonnier، نويسنده , , Victor Legrand، نويسنده , , Eulogio Garcia، نويسنده , , Carlos Macaya، نويسنده , , Eduardo Sousa، نويسنده , , Wim van der Giessen، نويسنده , , Antonio Colombo، نويسنده , , Ricardo Seabra-Gomes، نويسنده , , Ferdinand Kiemeneij، نويسنده , , Peter Ruygrok، نويسنده , , John Ormiston، نويسنده , , Hakan Emanuelsson، نويسنده , , Jean Fajadet، نويسنده , , Mi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
9
From page :
673
To page :
681
Abstract :
Background The multicentre, randomised Benestent-II study investigated a strategy of implantation of a heparincoated Palmar-Schatz stent plus antiplatelet drugs compared with the use of balloon angioplasty in selected patients with stable or stabilised unstable angina, with one or more de-novo lesions, less than 18 mm long, in vessels of diameter 3 mm or more. Methods 827 patients were randomly assigned stent implantation (414 patients) or standard balloon angioplasty (413 patients). The primary clinical endpoint was event-free survival at 6 months, including death, myocardial infarction, and the need for revascularisation. The secondary endpoints were the restenosis rate at 6 months and the cost-effectiveness at 12 months. There was also one-to-one subrandomisation to either clinical and angiographic follow-up or clinical follow-up alone. Analyses were by intention to treat. Findings Four patients (one stent group, three angioplasty group) were excluded from analysis since no lesion was found. At 6 months, a primary clinical endpoint had occurred in 53 (12·8%) of 413 patients in the stent group and 79 (19·3%) of 410 in the angioplasty group (p=0·013). This significant difference in clinical outcome was maintained at 12 months. In the subgroup assigned angiographic follow-up, the mean minimum lumen diameter was greater in the stent group than in the balloon-angioplasty group, (1·89 [SD 0·65] vs 1·66 [0·57] mm, p=0·0002), which corresponds to restenosis rates (diameter stenosis ≥50%) of 16% and 31% (p=0·0008). In the group assigned clinical follow-up alone, event-free survival rate at 12 months was higher in the stent group than the balloon-angioplasty group (0·89 vs 0·79, p=0·004) at a cost of an additional 2085 Dutch guilders (US$1020) per patient. Interpretation Over 12-month follow-up, a strategy of elective stenting with heparin-coated stents is more effective but also more costly than balloon angioplasty.
Journal title :
The Lancet
Serial Year :
1998
Journal title :
The Lancet
Record number :
578168