• Title of article

    Extensive facial damage caused by a blast injury arising from a 6 volt lead accumulator

  • Author/Authors

    S. K. Singh، نويسنده , , P. Jain، نويسنده , , J. K. Sinha ، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    3
  • From page
    149
  • To page
    151
  • Abstract
    Low-voltage electrical injuries are relatively uncommon. Injury caused by flow of heavy current due to short-circuiting a low-voltage battery has not been described in the English literature. A 9-year-old boy connected two thin household electrical wires to the two terminals of a 6 volt (lead accumulator) battery and pressed the other two ends between his teeth. This resulted in a blast causing a compound comminuted fracture of the mandible and extensive tissue damage in the oral cavity. The low internal resistance of a lead accumulator (˜ 0.03 ohms) permits the flow of a heavy current (˜ 200 amps) when short-circuited. This instantaneously vaporises a minuscule portion of wire at ˜ 2000 K resulting in a sudden rise of intraoral pressure to 30 kg cm–2leading to tissue damage.
  • Keywords
    lead accumulator , Blast injury , low-voltage electrical injury , Facial injury
  • Journal title
    Journal of Plastic , Reconstructive and Aesthetic Surgery
  • Serial Year
    1999
  • Journal title
    Journal of Plastic , Reconstructive and Aesthetic Surgery
  • Record number