Title of article :
Procedural results and late clinical outcomes after percutaneous interventions using long (≥25 mm) versus short (<20 mm) stents
Author/Authors :
Ran Kornowski، نويسنده , , Balram Bhargava، نويسنده , , D. M. Shmuel Fuchs، نويسنده , , Alexandra J. Lansky، نويسنده , , Lowell F. Satler، نويسنده , , Augusto D. Pichard، نويسنده , , Mun K. Hong، نويسنده , , Kenneth M. Kent، نويسنده , , Roxana Mehran، نويسنده , , Gregg W. Stone، نويسنده , , Martin B. Leon، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Abstract :
OBJECTIVES
To evaluate clinical outcomes after the use of long coronary stents.
BACKGROUND
The use of long slotted-tube stents has been recently approved in the U.S. to treat long lesions or dissections. Procedural success and long-term outcomes of long versus short stents have not been established.
METHODS
We evaluated procedural success, major in-hospital complications, target lesion revascularization and long-term (one year) clinical outcomes in 1,226 consecutive patients (1,259 native coronary lesions) who underwent a single vessel intervention using a single long (≥25 mm, 116 patients) or short (<20 mm, 1,110 patients) tubular-slotted stent.
RESULTS
Patients treated with long stents had more diffuse (>10 mm length) lesions (63% vs. 28%, p = 0.001). The mean stent length was 28 ± 5 mm versus 15 ± 2 mm for long versus short stent groups (p = 0.001). Overall procedural success was similar in the long versus short stent groups (96% vs. 98%, p = 0.08). However, major in-hospital complications tended to occur more frequently in patients treated with longer stents (3.4% vs. 1.0%, p = 0.04). The rate of periprocedural non-Q-wave myocardial infarction (MI) (creatine kinase-MB ≥5 times normal) was notably higher after long stent implantation (23% vs. 11%, p = 0.001). Target lesion revascularization at one year was 14.5% vs. 13.8% (p = 0.69), and target vessel revascularization rate was 19.6% vs. 17.3% (p = 0.41) in the long versus short stent group, respectively. There was no difference in one year mortality (2.5% vs. 3.5%, p = 0.49) or Q-wave MI (2.7% vs. 1.2%, p = 0.48), and the overall cardiac event-free survival was similar for the two groups (81%).
CONCLUSIONS
The use of single coronary long (≥25 mm) versus short (<20 mm) stents is associated with: 1) somewhat increased major procedural complications, 2) significantly higher frequency of periprocedural non-Q-wave MIs, and 3) equivalent repeat revascularization risk and cardiac event-free survival out-of-hospital up to one year.
Keywords :
odds ratio , QCA , quantitative coronary angiography , TIMI , Thrombolysis In Myocardial Infarction , TLR , target lesion revascularization , CK , TVR , creatinine kinase , target vessel revascularization , IVUS , intravascular ultrasound , MB , myocardial band , MI , myocardial infarction , OR
Journal title :
JACC (Journal of the American College of Cardiology)
Journal title :
JACC (Journal of the American College of Cardiology)