Title of article :
Pacing stress echocardiography: an alternative to pharmacologic stress testing
Author/Authors :
Shaul Atar، نويسنده , , Tomoo Nagai، نويسنده , , Bojan Cercek، نويسنده , , Tasneem Z. Naqvi، نويسنده , , Huai Luo، نويسنده , , Robert J. Siegel، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
7
From page :
1935
To page :
1941
Abstract :
OBJECTIVES We sought to evaluate the diagnostic accuracy and feasibility of bedside pacing stress echocardiography (PASE) as a potential substitute for pharmacologic stress echocardiography in patients admitted to the hospital with new-onset chest pain or worsening angina pectoris. BACKGROUND Accurate and rapid noninvasive identification and evaluation of the extent of coronary artery disease (CAD) is essential for optimal management of these patients. METHODS Bedside transthoracic stress echocardiography was performed in 54 consecutive patients admitted to a community hospital with new-onset chest pain, after acute myocardial infarction had been excluded. We used 10F transesophageal pacing catheters and a rapid and modified pacing protocol. The PASE results were validated in all patients by coronary angiography performed within 24 h of the test. Significant CAD was defined as ≥75% stenosis in at least one major epicardial coronary artery. RESULTS The sensitivity of PASE for identifying patients with significant CAD was 95%, specificity was 87% and accuracy was 92%. The extent of significant CAD (single- or multivessel disease) was highly concordant with coronary angiography (kappa = 0.73, p < 0.001). Pacing stress echocardiography was well tolerated, and only 4% of the patients had minor adverse events. The mean rate–pressure product at peak pacing was 22,313 ± 5,357 beats/min per mm Hg, and heart rate >85% of the age-predicted target was achieved in 94% of patients. The average duration of the bedside PASE test, including image interpretation, was 38 ± 6 min. CONCLUSIONS Bedside PASE is rapid, tolerable and accurate for identification of significant CAD in patients admitted to the hospital with new-onset chest pain or worsening angina pectoris.
Keywords :
coronary artery disease , DSE , dobutamine stress echocardiography , ECG , electrocardiography , PASE , pacing stress echocardiography , SPECT , Single-photon emission computed tomography , CAD
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2000
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
596231
Link To Document :
بازگشت