Title of article :
Fractional flow reserve, absolute and relative coronary blood flow velocity reserve in relation to the results of technetium-99m sestambi single-photon emission computed tomography in patients with two-vessel coronary artery disease
Author/Authors :
Steven A. J. Chamuleau، نويسنده , , Martijn Meuwissen، نويسنده , , Berthe L. F. van Eck-Smit، نويسنده , , Karel T. Koch، نويسنده , , Angelina de Jong، نويسنده , , Robbert J. de Winter، نويسنده , , Carl E. Schotborgh، نويسنده , , Matthijs Bax، نويسنده , , Hein J. Verberne، نويسنده , , Jan G. P. Tijssen، نويسنده , , Jan J. Piek، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
7
From page :
1316
To page :
1322
Abstract :
OBJECTIVES We sought to perform a direct comparison between perfusion scintigraphic results and intracoronary-derived hemodynamic variables (fractional flow reserve [FFR]; absolute and relative coronary flow velocity reserve [CFVR and rCFVR, respectively]) in patients with two-vessel disease. BACKGROUND There is limited information on the diagnostic accuracy of intracoronary-derived variables (CFVR, FFR and rCFVR) in patients with multivessel disease. METHODS Dipyridamole technetium-99m sestambi (MIBI) single-photon emission computed tomography (SPECT) was performed in 127 patients. The presence of reversible perfusion defects in the region of interest was determined. Within one week, angiography was performed; CFVR, rCFVR and FFR were determined in 161 coronary lesions after intracoronary administration of adenosine. The predictive value for the presence of reversible perfusion defects on MIBI SPECT of CFVR, rCFVR and FFR was evaluated by the area under the curve (AUC) of the receiver operating characteristics curves. RESULTS The mean percentage diameter stenosis was 57% (range 35% to 85%), as measured by quantitative coronary angiography. Using per-patient analysis, the AUCs for CFVR (0.70 ± 0.052), rCFVR (0.72 ± 0.051) and FFR (0.76 ± 0.050) were not significantly different (p = NS). The percentages of agreement with the results of MIBI SPECT were 76%, 78% and 77% for CFVR, rCFVR and FFR, respectively. Per-lesion analysis, using all 161 measured lesions, yielded similar results. CONCLUSIONS The diagnostic accuracy of three intracoronary-derived hemodynamic variables, as compared with the results of perfusion scintigraphy, is similar in patients with two-vessel coronary artery disease. Cut-off values of 2.0 for CFVR, 0.65 for rCFVR and 0.75 for FFR can be used for clinical decision-making in this patient cohort. Discordant results were obtained in 23% of the cases that require prospective evaluation for appropriate patient management.
Keywords :
rapid platelet-function assay , TRAP , ADP , fluorescein isothiocyanate , GP , Glycoprotein , MAb , FITC , thrombin receptor activating peptide , monoclonal antibody , PE , RPFA , Phycoerythrin , adenosine diphosphate
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2001
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
596517
Link To Document :
بازگشت