Title of article :
Decreased plasma concentration of brain natriuretic peptide as a potential indicator of cardiac recovery in patients supported by mechanical circulatory assist systems
Author/Authors :
Ralf Sodian، نويسنده , , Matthias Loebe، نويسنده , , Christoph Schmitt، نويسنده , , Evgenij V. Potapov، نويسنده , , Henryk Siniawski، نويسنده , , Johannes Müller، نويسنده , , Harald Hausmann، نويسنده , , Heinz R. Zurbruegg، نويسنده , , Yuguo Weng، نويسنده , , Roland Hetzer، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
8
From page :
1942
To page :
1949
Abstract :
OBJECTIVES We sought to investigate the relationship between the plasma concentration of brain natriuretic peptide (BNP), echocardiographic findings and the clinical outcome of patients supported with ventricular assist devices (VADs) to determine the role of BNP as a predictor for cardiac recovery. BACKGROUND Ventricular unloading in patients with end-stage heart failure supported by VADs may lead to myocardial recovery. The BNP is produced in the myocardium in response to chronic volume overload, but the effects on it of ventricular unloading by VADs are largely unknown. METHODS Twenty-one patients diagnosed with nonischemic cardiomyopathy and supported by VADs were evaluated for echocardiographic data and blood chemistry including BNP. They were divided into patients who died while on mechanical support (group I; N = 9), patients who were transplanted (group II; N = 8) and patients who were successfully weaned off the system and did not require transplantation (group III; N = 4). RESULTS Brain natriuretic peptide plasma concentrations decreased significantly after initiation of mechanical circulatory support (p = 0.017). Furthermore, the changes in BNP plasma concentrations showed a faster decrease to normal levels within the first week after implantation of the VAD in patients who were weaned off the system (group III) compared to patients in group I and group II. CONCLUSIONS This study shows that ventricular unloading with VADs decreases BNP plasma concentrations in patients who suffer from end-stage heart failure. Furthermore, we hypothesize that an early decrease of BNP plasma concentration may be indicative of recovery of ventricular function during mechanical circulatory support.
Keywords :
TEE , VAD , Ventricular assist device , ANP , atrial natriuretic peptide , brain natriuretic peptide , BNP , BVAD , biventricular assist device , LVAD , left ventricular assist device , LVEF , left ventricular ejection fraction , New York Heart Association , transesophageal echocardiography , NYHA
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2001
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
596977
Link To Document :
بازگشت