• Title of article

    QRST subtraction combined with a pacemap catalogue for the prediction of ectopy source by surface electrocardiogram in patients with paroxysmal atrial fibrillation

  • Author/Authors

    Kee-Joon Choi، نويسنده , , Dipen C. Shah، نويسنده , , Pierre Jaïs، نويسنده , , Meleze Hocini، نويسنده , , Laurent Macle، نويسنده , , Christophe Scavée، نويسنده , , Rukshen Weerasooriya، نويسنده , , Florence Raybaud، نويسنده , , Jacques Clementy، نويسنده , , Michel Haïssaguerre، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    9
  • From page
    2013
  • To page
    2021
  • Abstract
    Objectives This study evaluated the use of ectopic P-wave morphology to localize pulmonary vein (PV) and non-PV sources of atrial ectopics in patients with paroxysmal atrial fibrillation (PAF). Background The vectorial information embodied in the morphology of ectopic P waves is concealed by overlying T waves. Methods The P-wave morphology of 56 ectopics was prospectively analyzed in 44 patients with PAF (age, 52 ± 12 years; 36 male) by subtracting the adjacent QRST from the QRST-ectopic P-wave complex using custom-designed software. Subtraction fidelity was validated in 15 other patients (55 ± 19 years, 11 male) by comparing drive beats with simulated ectopics (S2 from the same site) unmasked by subtracting overlying QRST. An algorithm combined with PV pacemaps was used to predict PV sources. Subtracted ectopic P-wave morphologies after PV disconnection were compared with PV and non-PV site pacemaps. Localization was confirmed by mapping and successful ablation. Results A ≥10-lead electrocardiogram (ECG) match was observed in 92% of 644 simulated ectopics (coupling intervals: 190 to 520 ms). In PAF patients, 37 spontaneous ectopics originated from the PV, while 19 were noted after PV disconnection. Using the P-wave algorithm alone, correct prediction of PV origin was achieved in 30/37 ectopics (81%). Combination with PV pacemaps allowed correct prediction in 34/37 (92%). After PV disconnection, ECG localization predicted successful ablation sites in 16/19 (84%). Conclusions Comparison of subtracted ectopic P waves with a pacemap catalogue provides a simple and accurate 12-lead ECG-based method for localization, which can facilitate ablation of arrhythmia triggers irrespective of origin from the PV or elsewhere.
  • Keywords
    PV , paroxysmal atrial fibrillation , superior vena cava , AF , inferior vena cava , PAF , IVC , pulmonary vein , Atrial fibrillation , SVC
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2002
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    597651