Title of article :
Observations on Performance of Three-Tube Pitot Probe
Author/Authors :
Rajaratnam، N. نويسنده , , Wu، S. نويسنده , , Kabir، M. R. نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2000
Pages :
-711
From page :
712
To page :
0
Abstract :
This technical note discusses two questions related to three-tube (pitch or yaw) pitot probes, which are used for measuring the velocity zero, it is important to know the error this causes in the measurement of the velocity vector. Calibration experiments on a pitch probe showed that as long as the yaw angle is less than 14°, the relative error in the velocity measured by the pitch probe is less than 3% and the error in the pitch angle is less than 1°. Typically a pitch or yaw probe can only be used when the angle of attack is less than approximately 50°. The second part of this work addresses the practical issues associated with pretilting the probe to measure flows at angles greater than 50°.
Keywords :
Rondeletieae , Rubiaceae , essential oil , Tresanthera , secretory cavities , anatomy , Rustia
Journal title :
Journal of Hydraulic Engineering
Serial Year :
2000
Journal title :
Journal of Hydraulic Engineering
Record number :
59880
Link To Document :
بازگشت