Title of article
Glue aortoplasty repair of aortic dissection after coronary angioplasty
Author/Authors
Alsir A.M Ahmed، نويسنده , , Vaikom S Mahadevan، نويسنده , , Samuel W Webb، نويسنده , , Simon W MacGowan، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
3
From page
922
To page
924
Abstract
Aortic dissection complicating percutaneous transluminal coronary angioplasty is rare. We report the case of a 45-year-old man who after right coronary artery angioplasty with stenting, dissected that vessel to involve the aorta to the bifurcation. Surgical repair with Gelatin-Resorcinol-Formaldehyde (GRF) glue as opposed to prosthetic graft replacement of the ascending aorta was successful. The use of GRF glue is effective in the surgical treatment of aortic dissection after coronary angioplasty.