Title of article :
The initial experience with the ATS Medical mechanical cardiac valve prosthesis
Author/Authors :
Robert W Emery، نويسنده , , Guido J Van Nooten، نويسنده , , Peter J Tesar and for the Investigators for the ATS Clinical Open Pivot Heart Valve Food and Drug Administration Study، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
9
From page :
444
To page :
452
Abstract :
Background From May 1994 through October 2000, a total of 1,146 patients underwent valve replacement with the ATS Medical mechanical cardiac valve prosthesis under a study protocol approved by international ethics committees (non–United States participants) or under a United States Food and Drug Administration–approved Investigational Device Exemption study. The study took place at 19 domestic and three international centers. Methods As required by the Food and Drug Administration’s Heart Valve Guidance Document, only isolated implants were included in the study (double-valve implants were excluded), with operative and follow-up data collected from each center. Results Aortic valve replacement (AVR) was conducted in 801 patients (309 with coronary bypass) and mitral valve replacement (MVR) in 345 patients (78 with coronary bypass). Overall operative (≤ 30 days post implant) mortality was 2.1% (17 AVR = 2.1%, 7 MVR = 2.0%), 7 of which (AVR = 4, MVR = 3) were valve related. In 2,086 patient-years (1,459 AVR patient-years, 627 MVR patient-years) of follow-up, there were an additional 50 patient deaths of these, 18 were valve related, 9 due to anticoagulant related bleeding, 5 sudden/unexplained, and 1 each after stroke, thrombosis, prosthetic valve endocarditis, and thromboembolism. Late (>30 days post implant) valve-related complications included: transient and chronic thromboembolism (27 AVR (linearized rate 1.85%/patient-year) and 20 MVR (3.19%/patient-year), of which 11/47 (0.53%/patient-year) had chronic deficits, thrombosis (1 AVR = 0.07%/patient-year and 4 MVR = 0.64%/patient-year), paravalvular leak (10 AVR = 0.69%/patient-year and 8 MVR = 1.28%/patient-year), anticoagulant related hemorrhage (34 AVR = 2.33%/patient-year and 8 MVR = 1.28%/patient-year), prosthetic valve endocarditis (3 AVR = 0.21%/patient-year and 2 MVR = 0.32%/patient-year), and structural valve failure or dysfunction (0%). Echocardiographic gradients were proportional to valve size and did not significantly change over the follow-up period. Conclusions This study documented the ATS Medical mechanical cardiac valve prosthesis to be a valuable addition to the surgeon’s armamentarium in the treatment of cardiac valvular disease.
Journal title :
The Annals of Thoracic Surgery
Serial Year :
2003
Journal title :
The Annals of Thoracic Surgery
Record number :
606342
Link To Document :
بازگشت