    Dislocated wrap after previous reduction aortoplasty causes erosion of the ascending aorta

  • Author/Authors

    Infineon Technologies Matthias Bauer، نويسنده , , Onnen Grauhan، نويسنده , , Roland Hetzer، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    2
  • From page
    583
  • To page
    584
  • Abstract
    We report a patient with bicuspid aortic valve and dilatation of the ascending aorta who had previous aortic valve replacement and reduction aortoplasty with wrapping. After 4 years, reoperation because of coronary artery disease and paravalvular leakage revealed an erosion of the aortic wall due to dislocation of the wrap. This complication confirms the need for secure anchoring and good fitting of the Dacron wrap to avoid alterations of the underlying aortic wall.