Title of article :
Strategies to Manage Paraplegia Risk After Endovascular Stent Repair of Descending Thoracic Aortic Aneurysms
Author/Authors :
Albert T. Cheung، نويسنده , , Alberto Pochettino، نويسنده , , Michael L. McGarvey، نويسنده , , Jehangir J. Appoo، نويسنده , , Ronald M. Fairman، نويسنده , , Jeffrey P. Carpenter، نويسنده , , William G. Moser، نويسنده , , Edward Y. Woo، نويسنده , , Joseph E. Bavaria، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
10
From page :
1280
To page :
1289
Abstract :
Background Paraplegia is a recognized complication after endovascular stent repair of descending thoracic aortic aneurysms. A management algorithm employing neurologic assessment, somatosensory evoked potential monitoring, arterial pressure augmentation, and cerebrospinal fluid drainage evolved to decrease the risk of postoperative paraplegia. Methods Patients in thoracic aortic aneurysm stent trials from 1999 to 2004 were analyzed for paraplegic complications. Lower extremity strength was assessed after anesthesia and in the intensive care unit. A loss of lower extremity somatosensory evoked potential or lower extremity strength was treated emergently to maintain a mean arterial pressure 90 mmHg or greater and a cerebrospinal fluid pressure 10 mm Hg or less. Results Seventy-five patients (male = 49, female = 26, age = 75 ± 7.4 years) had descending thoracic aortic aneurysms repaired with endovascular stenting. Lumbar cerebrospinal fluid drainage (n = 23) and somatosensory evoked potential monitoring (n = 15) were performed selectively in patients with significant aneurysm extent or with prior abdominal aortic aneurysm repair (n = 17). Spinal cord ischemia occurred in 5 patients (6.6%); two had lower extremity somatosensory evoked potential loss after stent deployment and 4 developed delayed-onset paraplegia. Two had full recovery in response to arterial pressure augmentation alone. Two had full recovery and one had near-complete recovery in response to arterial pressure augmentation and cerebrospinal fluid drainage. Spinal cord ischemia was associated with retroperitoneal bleed (n = 1), prior abdominal aortic aneurysm repair (n = 2), iliac artery injury (n = 1), and atheroembolism (n = 1). Conclusions Early detection and intervention to augment spinal cord perfusion pressure was effective for decreasing the magnitude of injury or preventing permanent paraplegia from spinal cord ischemia after endovascular stent repair of descending thoracic aortic aneurysm. Routine somatosensory evoked potential monitoring, serial neurologic assessment, arterial pressure augmentation, and cerebrospinal fluid drainage may benefit patients at risk for paraplegia.
Journal title :
The Annals of Thoracic Surgery
Serial Year :
2005
Journal title :
The Annals of Thoracic Surgery
Record number :
609025
Link To Document :
بازگشت