Title of article :
Intraoperative, Radio-Guided Sentinel Lymph Node Mapping in 110 Nonsmall Cell Lung Cancer Patients
Author/Authors :
Witold Rzyman، نويسنده , , Ole M. Hagen، نويسنده , , Rafal Dziadziuszko، نويسنده , , Grazyna Kobierska-Gulida، نويسنده , , Andrzej Karmolinski، نويسنده , , Inger M. Lothe، نويسنده , , Almira Babovic، نويسنده , , Maciej Murawski، نويسنده , , Waldemar Paleczka، نويسنده , , Tomasz Jastrzebski، نويسنده , , Andrzej Kopacz، نويسنده , , Jacek Jassem، نويسنده , , Piotr Lass، نويسنده , , Jaroslaw Skokowski، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
6
From page :
237
To page :
242
Abstract :
Background Sentinel lymph node identification has been tested in lung cancer patients with conflicting results. The present study was designed to assess the sensitivity, negative predictive value, and accuracy of intraoperative sentinel lymph node mapping by means of a radio-guided method in patients with nonsmall cell lung cancer to find the most appropriate definition of sentinel lymph node and to evaluate the usefulness of different particle sizes of radiocolloid. Methods One hundred ten patients with clinically N0 nonsmall cell lung cancer were enrolled in the pilot study of intraoperative sentinel node identification. Four quadrants of the peritumoral tissue were injected with 2 mL of 0.5 mCi technetium-99m suspension. Four radiocolloids of different particle size were used. After complete lymphadenectomy, all resected lymph nodes were examined with hematoxylin-eosin staining. All sentinel nodes negative for metastases by routine staining were searched further for metastatic deposits with both serial sections and immunohistochemistry for cytokeratins. Results The radio-guided method had a high identification rate, a high sensitivity, and a high negative predictive value (100%, 87%, and 93%, respectively) when immunohistochemistry was considered. When standard hematoxylin and eosin staining was applied, sensitivity and negative predictive value of sentinel lymph node labeling was lower (74% and 89%, respectively). No significant differences were found in either the sensitivity or negative predictive value among the colloid solutions of different particle size used in radio labeling, although smaller particles have shown a tendency to produce better results. Conclusions The radio-guided technique provides efficient sentinel lymph node identification in lung cancer. Further studies are warranted to confirm the clinical utility of this strategy.
Journal title :
The Annals of Thoracic Surgery
Serial Year :
2006
Journal title :
The Annals of Thoracic Surgery
Record number :
609818
Link To Document :
بازگشت