Title of article :
Bi-Ventricular Circulatory Support With the Abiomed AB5000 System in a Patient With Idiopathic Refractory Ventricular Fibrillation
Author/Authors :
Li Zhang، نويسنده , , Emmanouil I. Kapetanakis، نويسنده , , Richard H. Cooke، نويسنده , , Leslie C. Sweet، نويسنده , , Steven W. Boyce، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
A 45-year-old man had life-threatening recurrent idiopathic ventricular fibrillation and persistent cardiogenic shock develop. The episodes of ventricular fibrillation were refractory to aggressive medical management; therefore an Abiomed AB5000 bi-ventricular support system was implanted for arrhythmia control. The device was able to maintain hemodynamic stability during the following 2 weeks. The patient was discharged from the hospital with fully recovered cardiac function.
Journal title :
The Annals of Thoracic Surgery
Journal title :
The Annals of Thoracic Surgery