• Title of article

    Cardiac Luxation to Facilitate Off-Pump Bilateral Lung Transplantation

  • Author/Authors

    Hester T. Visser، نويسنده , , Michiel E. Erasmus، نويسنده , , Tjark Ebels، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    2
  • From page
    329
  • To page
    330
  • Abstract
    To facilitate access to the left hilum during off-pump bilateral lung transplantation we used the Xpose 4™ apical suction device (Guidant Corp., Indianapolis, IN), an off-pump coronary bypass device to luxate the heart out of the pericardium. The effects on circulation and possible myocardial injury were studied in retrospect. We found the device to provide us with an elegant and nondamaging method to visualize the left hilum.
  • Journal title
    The Annals of Thoracic Surgery
  • Serial Year
    2007
  • Journal title
    The Annals of Thoracic Surgery
  • Record number