Title of article :
Subannular Perforation After Long-Lasting Aortic Valve Replacement Mimicking Mitral Insufficiency
Author/Authors :
Justus T. Strauch، نويسنده , , Jens Wippermann، نويسنده , , Henning Krep، نويسنده , , Thorsten Wahlers، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
3
From page :
311
To page :
313
Abstract :
We report a rare case of a patient diagnosed with mitral insufficiency grade III 12 years after mechanical aortic valve replacement. Transesophageal echocardiography discribed an eccentric mitral regurgitation-type systolic jet with color flow evidence of communication between left venticle and atrium. Surgical intervention showed a circular defect in the mitral-aortic intervalvular fibrosa area, after removal of the mechanical valve, located beneath the noncoronary sinus causing the echocardiography-detected mitral insufficiency. A pericardial patch was trimmed to the appropriate size, and the defect was closed. The aortic valve was replaced by a stented pericardial bioprosthesis.
Journal title :
The Annals of Thoracic Surgery
Serial Year :
2008
Journal title :
The Annals of Thoracic Surgery
Record number :
611285
Link To Document :
بازگشت