Title of article :
Novel Technique for Aortic Arch Surgery Under Mild Hypothermia
Author/Authors :
Aristotelis Panos، نويسنده , , Patrick-Olivier Myers، نويسنده , , Afkskendiyos Kalangos، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
2
From page :
347
To page :
348
Abstract :
We present our initial experience in 5 patients for open aortic arch repair with continuous antegrade perfusion of the brain and of the lower body by means of direct cannulation of the right axillary artery and of the descending aorta with a venous cannula (DLP 91037 cannula [Medtronic Inc, Minneapolis, MN]) for systemic perfusion under mild hypothermia (30°C). This mode of perfusion allows safe open repair of the aortic arch, short aortic cross clamping, and CPB times associated to all the known advantages of the mild hypothermia; this technique could have the potential to be generally applicable in surgeries for aortic arch repairs after further evaluation.
Journal title :
The Annals of Thoracic Surgery
Serial Year :
2008
Journal title :
The Annals of Thoracic Surgery
Record number :
611303
Link To Document :
بازگشت