Title of article :
Quantitative Shunt Imaging in the Evaluation of Therapeutic Surgery in a Patient With Pulmonary Arteriovenous Malformation
Author/Authors :
Tunc Ones، نويسنده , , Fuat Dede، نويسنده , , Refik Erdim، نويسنده , , Tanju Yusuf Erdil، نويسنده , , Sabahat Inanir، نويسنده , , Mustafa Yüksel، نويسنده , , Halil Turgut Turoglu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
3
From page :
649
To page :
651
Abstract :
A case of pulmonary arteriovenous malformation (PAVM) in a 32-year-old woman who underwent successful left upper lobectomy is presented. A whole-body technetium-99m-labeled macro-aggregated albumin scan was used to demonstrate intrapulmonary right-to-left shunt, and shunt fraction was calculated as 39%. The patient underwent a follow-up scan after the operation; shunt fraction was calculated to be within normal limits (5%). The whole-body technetium-99m-labeled macro-aggregated albumin scan seems to be a simple and noninvasive test in the demonstration and quantitation of the degree of the right-to-left shunt in pulmonary arteriovenous malformation. The whole-body technetium-99m-labeled macro-aggregated albumin scan may also be useful for evaluation of the hemodynamic changes after surgical treatment and follow-up of the patients with pulmonary arteriovenous malformation.
Journal title :
The Annals of Thoracic Surgery
Serial Year :
2008
Journal title :
The Annals of Thoracic Surgery
Record number :
611837
Link To Document :
بازگشت