Title of article :
The OʹBrien-Angell stentless porcine valve: Early results with 150 implants
Author/Authors :
Ulrik Hvass، نويسنده , , Didier Chatel، نويسنده , , Patrik Assayag، نويسنده , , Mohammad Ouroudji، نويسنده , , Yves Pansard، نويسنده , , Catherine Lenormand، نويسنده , , Thierry Laperche MD، نويسنده , , Jean-Pol Depoix، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1995
Pages :
4
From page :
414
To page :
417
Abstract :
From August 1991 to June 1994, 150 patients underwent aortic valve replacement with the OʹBrien-Angell stentless porcine xenograft (Bravo Cardiovascular Model 300, Cryolife, Atlanta, GA). To establish trends we analyzed three consecutive groups of 50 patients. We found significant differences in low postoperative gradients (mean ≤ 10 mm Hg): 24% in group 1, 42% in group 2, and 96% in group 3. Comparing groups 1 and 3, gradients were significantly lower in all valve sizes. The difference is credited to better supraannular positioning of the valve, which is the key to the learning curve. Trivial central regurgitation was present in the three groups at 6%, 12%, and 0%, respectively. Peripheral regurgitation was trivial in 6%, 8%, and 0%, and mild to moderate in 4%, 2% and 0%, respectively. Seventy-eight of 107 patients with an available follow-up exceeding 1 year had noninvasive controls. Two early cases with moderate perivalvular leaks evolved to moderately severe leaks. Two valves were explanted. The OʹBrien-Angell stentless valve is easy to handle and correct supraannular positioning provides excellent hemodynamic results.
Journal title :
The Annals of Thoracic Surgery
Serial Year :
1995
Journal title :
The Annals of Thoracic Surgery
Record number :
612610
Link To Document :
بازگشت