Title of article :
Allograft Aortic Root Replacement in Prosthetic Aortic Valve Endocarditis: A Review of 32 Patients
Author/Authors :
Karl M Dossche MD، نويسنده , , Joseph J Defauw MD، نويسنده , , Sjef M Ernst MD، نويسنده , , Ton W Craenen MD، نويسنده , , Bartelt M.De Jongh MD، نويسنده , , Aart Brutel de la Rivière MD، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
6
From page :
1644
To page :
1649
Abstract :
Background. This study was conducted to evaluate allograft aortic root replacement in the setting of complicated prosthetic valve endocarditis with extensive annular destruction. Methods. From January 1990 through March 1996, 32 patients diagnosed with complicated prosthetic valve endocarditis underwent allograft root replacement. Mean age was 58.3 ± 13.2 years; 23 patients were men. Mean preoperative New York Heart Association functional class was 3.4. Staphylococcus epidermidis (50%) and Enterococcus faecalis (19%) were the predominant causative microorganisms. Annular abscesses were found in 26 patients (81%), aortic-mitral discontinuity in 14 patients (43%), and left ventricular-aortic discontinuity in 11 patients (34%). A cryopreserved allograft was used in 31 patients (97%) and a fresh antibiotic-treated allograft was used in 1 patient (3%). Mean aortic cross-clamp time was 150 ± 29 minutes. Mean duration of the postoperative antibiotic treatment was 38.5 ± 11.8 days. Results. There were three operative deaths (9.4%); causes of death were multiorgan failure in 2 patients (6.2%) and low cardiac output in 1 patient (3.2%). Six patients (18%) had complete heart block (4 patients already before the operation), 3 patients (9.4%) had temporary respiratory insufficiency, and 1 patient (3.2%) needed temporary hemodialysis. Mean follow-up was 37.4 ± 22.4 months. Two late deaths occurred: 1 patient had recurrent endocarditis, leading to a false aneurysm, and died at reoperation; another patient died of lung cancer. Actuarial 5-year survival was 87.3% (70% confidence interval, 76.8% to 97.8%); actuarial 5-year freedom from recurrent endocarditis was 96.5% (70% confidence interval, 90.0% to 100%) Conclusions. Allograft aortic root replacement is a valuable technique in the complex setting of prosthetic valve endocarditis with involvement of the periannular region. Mortality and morbidity are low.
Journal title :
The Annals of Thoracic Surgery
Serial Year :
1997
Journal title :
The Annals of Thoracic Surgery
Record number :
614322
Link To Document :
بازگشت