Title of article :
Reversible snaring for proper prosthetic seating during valve replacement
Author/Authors :
Fritz J. Baumgartner، نويسنده , , Bassam O. Omari، نويسنده , , Lillia Stuart، نويسنده , , Jeffrey C. Milliken MD، نويسنده , , Ronald J. Nelson، نويسنده , , John M. Robertson، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
2
From page :
957
To page :
958
Abstract :
A method of reversible suture snaring is described for evaluating the final valve seating and positioning before knot tying of valve sutures. This allows for alteration of the operative plan before investing substantial ischemic time in a nonfunctional result. The procedure has been used in 577 consecutive prosthetic valve replacements in the past 5 years. The technique maintains proper seating while the valve is permanently anchored in place.