Title of article
Tube device for facilitating distal anastomosis in aortic arch replacement
Author/Authors
Tadahiro Sasajima، نويسنده , , Kazutomo Goh، نويسنده , , Hidenori Asada، نويسنده , , Tokihito Sugawara، نويسنده , , Norifumi Ohtani، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
2
From page
1436
To page
1437
Abstract
The technique of placing an inverted graft into the descending thoracic aorta facilitates and secures the distal anastomosis in aortic arch replacement, especially in the anastomosis beyond the transverse arch. We developed a simple technique using a pair of thin-walled tubes to enable the arch graft, with its four branches, to be smoothly inserted into the flaccid, normal-caliber descending aorta. The use of these tubes simplified the procedure, resulting in time saving.
Journal title
The Annals of Thoracic Surgery
Serial Year
1998
Journal title
The Annals of Thoracic Surgery
Record number
615422
Link To Document