Title of article
The use of the Ligasure for hemostasis during thyroid lobectomy
Author/Authors
Sandeepa Musunuru، نويسنده , , Sarah Schaefer، نويسنده , , Herbert Chen، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
4
From page
382
To page
385
Abstract
Background
The Ligasure electrothermal vessel sealer (Valleylab, Boulder, CO) has been introduced as a new method for hemostasis during thyroidectomy. We hypothesized that the use of Ligasure would potentially reduce operative time during thyroid surgery.
Methods
From 2001 to 2005, 150 patients had a thyroid lobectomy by a single surgeon. Data from these patients were prospectively collected in a database and retrospectively analyzed.
Results
Of the 150 patients, 51 underwent thyroid lobectomy with the use of the Ligasure and 99 patients underwent conventional ligation of vessels. There were no differences between groups with regard to demographic factors, thyroid gland pathology, or complications. Operative time was significantly shortened by 40 minutes in patients who had surgery with the Ligasure.
Conclusion
In patients undergoing thyroid lobectomy, the use of the Ligasure decreases operating room time and is associated with no increase in complications. Thus, we advocate the routine use of this technology during thyroid surgery.
Keywords
LigaSure , Operative time , Vessel sealer , Thyroidectomy , Thyroid lobectomy
Journal title
The American Journal of Surgery
Serial Year
2008
Journal title
The American Journal of Surgery
Record number
618999