Title of article :
Comparison of carbon dioxide and iodinated contrast for cavography prior to inferior vena cava filter placement
Author/Authors :
Robert B. Holtzman، نويسنده , , Lawrence Lottenberg، نويسنده , , Thomas Bass، نويسنده , , Angeleke Saridakis، نويسنده , , Vicki J. Bennett، نويسنده , , Eddy H. Carrillo، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
Background
The use of iodinated contrast in the critically ill trauma patient has been associated with the development of acute renal failure. The low incidence of nephrotoxicity associated with carbon dioxide (CO2) makes it an ideal contrast agent for cavography. However, the use of CO2 has been limited, because reportedly it underestimates the diameter of the inferior vena cava (IVC).
Methods
During a 6-month period (January 2000 through June 2000), 25 adult trauma patients required IVC filter placement. Bedside cavagrams using CO2 followed by iodinated contrast were employed to determine the diameter of the IVC and the anatomy of the renal veins.
Results
Using CO2 injection for cavography, we were able to determine the diameter of the IVC and the anatomy of the renal veins in all patients. Furthermore, when CO2 cavography was compared with the results obtained with iodinated contrast, the difference in diameter of the IVC was within 1 mm.
Conclusions
Based on these data, it was determined that CO2 cavagrams accurately reflect the diameter of the IVC and the anatomy of the renal veins. Additionally, CO2 cavagrams can be safely performed in the intensive care unit during bedside placement of IVC filters.
Keywords :
Carbon dioxide , Cavography , Inferior vena cava filter
Journal title :
The American Journal of Surgery
Journal title :
The American Journal of Surgery