Title of article
A fuzzy logic approach to fire detection in aircraft dry bays and engine compartments
Author/Authors
S.Y.، Foo, نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
-1160
From page
1161
To page
0
Abstract
In this paper, a fuzzy logic approach is applied to detect hydrocarbon fires in aircraft dry bays and engine compartments. The inputs to the fuzzy system consist of a set of statistical measures derived from the histogram and image subtraction analyses of successive image frames. Specifically, fuzzy rules based on the median, standard deviation, and normalized firstorder moment statistical measures of histogram data and the mean statistical measure of image subtraction data of successive frames are used to compute the probability of a fire event. This fuzzy logic approach is also tested for false alarms such as those due to flashlights and high-power halogen lights. It is shown that image subtraction analysis can be used to accurately distinguish fires from false alarms