Title of article
Effect of Lateral Deflector on Outlet Cavity Lengths
Author/Authors
Nie، Meng-Xi نويسنده , , Wang، Xu-Shenng نويسنده , , Wu، Guang-Hao نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
-535
From page
536
To page
0
Abstract
Experimental results indicate that an additional lateral deflector built on the outlet can increase the cavity length in aerators with a sudden vertical drop and lateral enlargement. Observation shows that the cavity length is affected by both the vertical and lateral dimensions of the deflector. A larger deflector increases the cavity length substantially and connects the bottom cavity with the sidewall ones which results in more sufficient aeration. However, the backward flow on the bottom may reduce the length of bottom cavity and the effectiveness of aeration. Factors affecting the bottom cavity length, including the slope of the outlet, the bucket angle of sill, and the shape of lateral deflector, should be included in the estimation of the bottom cavity length. Based on test results, an equation has been proposed to predict the cavity length.
Keywords
Disordered systems , Lattice gas dynamics , Exclusion process , Hydrodynamic limit
Journal title
JOURNAL OF HYDROULIC ENGINEERING
Serial Year
2003
Journal title
JOURNAL OF HYDROULIC ENGINEERING
Record number
63338
Link To Document