Title of article
Prospective surveillance of phlebitis associated with peripheral intravenous catheters
Author/Authors
Tal Malach، نويسنده , , Ziona Jerassy، نويسنده , , Bernard Rudensky، نويسنده , , Yechiel Schlesinger، نويسنده , , Etty Broide، نويسنده , , Oded Olsha، نويسنده , , Amos M. Yinnon، نويسنده , , David Raveh، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
5
From page
308
To page
312
Abstract
Background
Guidelines have been published for prevention of phlebitis associated with peripheral intravenous catheters (IVC), but this complication continues to occur. We sought to determine the rate of phlebitis associated with peripheral IVCs to identify predictors for phlebitis and to isolate pathogenic bacteria from phlebitic catheter tips.
Methods
Nine-point prevalence studies were conducted during the years 1996-2003 of all hospitalized patients with a peripheral IVC. During the last 3 surveys, conducted in 2003, phlebitic lines were removed, and, for each line, 1 to 2 nonphlebitic lines, in place for 48 to 72 hours, were removed and cultured as controls. In between these surveys, findings and guidelines for improvement were distributed to the staff.
Results
During these surveys, 40% ± 8% of hospitalized patients had a peripheral IVC. The rate of peripheral IVC-associated phlebitis decreased from 12.7% (20/157) in 1998 to 2.6% (5/189) in 2003 (P < .01). Factors significantly associated with phlebitis included pain (P < .001), presence of the catheter for longer than 3 days (P < .05), and cleanliness of the dressing (P < .01).
Conclusion
The rate of phlebitis associated with peripheral intravenous catheters decreased significantly throughout the study period. The identification of predictors for phlebitis and the dissemination of this information in an educational drive may have contributed to this improvement.
Journal title
American Journal of Infection Control (AJIC)
Serial Year
2006
Journal title
American Journal of Infection Control (AJIC)
Record number
636367
Link To Document