Title of article :
Reducing the Occurrence of Short Onset Central Line Related Bacteremia
Author/Authors :
C.A. Kohan، نويسنده , , C. Ligi، نويسنده , , D.G. Dumigan، نويسنده , , T. Cooper، نويسنده , , J.M. Boyce، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
2
From page :
45
To page :
46
Abstract :
BACKGROUND/OBJECTIVES: Catheter Related Bloodstream Infections (CRBSIs) have been targeted for reduction at our 500-bed university-affiliated hospital since 2001. Prospective, house-wide surveillance for CRBSI revealed a cluster of CRBSIs with onset shortly after insertion (≤14 days) among patients with central catheters inserted in Interventional Radiology (IR) during the months of June through August 2002. METHODS: The use of Chloroprep®, a 2% CHG/70% alcohol skin prep (ALC/CHG) was introduced in June 2003. All IR staff were educated and validated on appropriate aseptic technique and skin prep using the new product. The occurrence of CRBSI initially decreased, but we did not observe a sustained reduction in infections. In April 2004, the use of a CHG sponge dressing (Biopatch®) was introduced. This product was used on all central catheters inserted in IR and removed at the first scheduled dressing change, 7 days following insertion. CRBSIs were identified by reviewing daily laboratory reports. A CRBSI was defined as a positive catheter tip culture with a corresponding positive peripheral blood culture in a patient with a central catheter in place. RESULTS: The mean rate of CRBSI in catheters inserted ≤14 days was 0.147 per 1000 patient days for the 7 quarters before the use of the CHG sponge. The CRBSI rate decreased in the 5 quarters following the intervention to 0.036 per 1000 patient days (p = 0.012). Following the implementation of the CHG sponge dressing, 7 cases occurred within the 14 day post insertion time period. Of these, all but one were identified after 8 days of insertion. CONCLUSIONS: Preparing insertion sites with ALC/CHG, together with use of CHG sponge dressings decreased our short-onset CRBSI occurrence. We have recently expanded the use of both products. The ALC/CHG will be used for the insertion of all central catheters. The CHG sponge is now used on all catheters with the exception of Ports and short-term lines inserted in the OR. It will also be replaced at each dressing change until the catheter is discontinued. One limitation of this study is that we expressed the incidence of infections as the number of CRBSIs per 1000 patient-days, instead of per 1000 catheter-days, which were not provided by IR. Although using catheter days would provide a more accurate estimate of CRBSI rates, we have no reason to believe that the number of catheters or catheter days used in our hospital decreased in the 4 years of this study.
Journal title :
American Journal of Infection Control (AJIC)
Serial Year :
2006
Journal title :
American Journal of Infection Control (AJIC)
Record number :
636417
Link To Document :
بازگشت