Title of article :
Polymerase chain reaction determination of RhC, Rhc, and RhE blood types: An evaluation of accuracy and clinical utility, ,
Author/Authors :
Jerome Yankowitz، نويسنده , , Sheng Li، نويسنده , , Carl P. Weiner and From the Departments of Obstetrics and Gynecology and Pediatrics University of Iowa College of Medicine.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
5
From page :
1107
To page :
1111
Abstract :
OBJECTIVE: Polymerase chain reaction amplification of a portion of the RhC/c/E/e gene could lead to a rapid, accurate determination of fetal RhC/c/E status. The purpose of this study was to evaluate the accuracy of this technique by testing for the first time a large number of deoxyribonucleic acid samples derived from individuals whose RhC/c/E status was established by standard serologic methods. We also evaluated the potential clinical utility of polymerase chain reaction to ascertain fetal antigen status. STUDY DESIGN: Samples were obtained from Centre dʹEtude du Polymorphisme Humain families used for studies of genetic variation (n = 655). Deoxyribonucleic acid was extracted by standard techniques. With few modifications, published primers and reaction conditions were used. Samples were digested with restriction enzymes yielding characteristic electrophoresis patterns for RhC/c/E. Clinical utility was assessed by review of all patients evaluated for erythrocyte sensitization. RESULTS: RhC-positive (n = 479), RhC-negative (n = 176), Rhc-positive (n = 524), Rhc-negative (n = 131), RhE-positive (n = 131) and RhE-negative (n = 524) samples were evaluated. The sensitivity of RhC/c and E typing by polymerase chain reaction was 98.3%, 98.1%, and 96.9%, respectively. The specificity of polymerase chain reaction for identifying the RhC/c/E antigens was 91.5%, 94.7%, and 99.2%, respectively. CONCLUSIONS: Although it would appear that use of polymerase chain reaction to establish RhC/c/E type could aid in evaluation of RhC/c/E sensitization, we are concerned about the instances of antigen-positive individuals characterized as antigen negative. Further study is necessary to determine if this reflects a polymorphism, mutation, a data coding error, or a combination. The Centre dʹEtude du Polymorphisme Humain database is known to contain such errors at a rate that may surpass the error rate of our testing. A second molecular technique could be used to achieve better accuracy in the ascertainment of Rh C/c/E type. On the basis of a review of our patient population, molecular deoxyribonucleic acid techniques now available could aid the management of erythrocyte sensitization in pregnancy in >96% of cases. (Am J Obstet Gynecol 1997;176:1107-11.)
Keywords :
POLYMERASE CHAIN REACTION , rhesus factor , amniocentesis , isoimmunization
Journal title :
American Journal of Obstetrics and Gynecology
Serial Year :
1997
Journal title :
American Journal of Obstetrics and Gynecology
Record number :
640227
Link To Document :
بازگشت