Title of article :
Nuchal thickness, urine β-core fragment level, and maternal age for Down syndrome screening,
Author/Authors :
R.O. Bahado-Singh، نويسنده , , A.U. Oz، نويسنده , , A. D. Flores، نويسنده , , D. Cermik، نويسنده , , E. Acuna، نويسنده , , M.J. Mahoney، نويسنده , , L. Cole، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
5
From page :
491
To page :
495
Abstract :
Objective: Our purpose was to report the midtrimester Down syndrome screening efficiency of a 2-analyte algorithm, urine β-core fragment (a metabolite of human chorionic gonadotropin) and nuchal thickness, along with maternal age in a high-risk population undergoing genetic amniocentesis. Method: Nuchal thickness, humerus length, and maternal urine β-core fragment levels were measured prospectively before genetic amniocentesis in 1360 singleton pregnancies, 21 (1.5%) of which had fetal Down syndrome. All analyte levels were expressed as multiples of the normal medians based on biparietal diameter. Backward-stepwise logistic regression was used to determine whether the markers were significant independent predictors of fetal Down syndrome. Matrix analysis was used to calculate an adjusted Down syndrome likelihood ratio for each patient based on the significant screening markers. Multiplication by age-related midtrimester risk gave the adjusted Down syndrome risk. The sensitivity and false-positive rates at different Down syndrome screening thresholds were used to generate a receiver-operator characteristics curve. The area under the curve was used to assess the value of this screening test. Results: On the basis of logistic regression, β-core fragment level (P< .00001), nuchal thickness (P< .00001), and maternal age (P< .03), but not humerus length (P = .332), were significant predictors of Down syndrome. At an adjusted risk threshold of > 1/60 the sensitivity and false-positive rate for Down syndrome were 85.7% and 4.9%, respectively, when β-core fragment level, nuchal thickness, and maternal age were used. Correspondence screening values at a risk threshold > 1/150 were 95.2% and 10.8%, respectively. The area under the receiver-operator characteristics curve was 0.9357 (SE = 0.0137), indicating that the algorithm is excellent for Down syndrome screening. Conclusion: In this study, a combination algorithm consisting of nuchal thickness, urine β-core fragment level, and maternal age had a high screening efficiency for Down syndrome. This algorithm should be investigated as a new option for women at high risk of having a fetus with Down syndrome. (Am J Obstet Gynecol 1999;180:491-5.)
Keywords :
Nuchal thickness , b-core fragment
Journal title :
American Journal of Obstetrics and Gynecology
Serial Year :
1999
Journal title :
American Journal of Obstetrics and Gynecology
Record number :
643176
Link To Document :
بازگشت