Title of article :
Transvaginal ultrasound–assisted gynecologic surgery: evaluation of a new device to improve safety of intrauterine surgery
Author/Authors :
Ilan E. Timor-Tritsch، نويسنده , , Rachel J. Masch، نويسنده , , Steven R. Goldstein، نويسنده , , Eliza Ng، نويسنده , , Ana Monteagudo، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
6
From page :
1074
To page :
1079
Abstract :
Objective The purpose of this study was to evaluate a new device that couples any standard transvaginal ultrasound transducer to a special tenaculum by means of a specially designed adaptor that enables real-time ultrasound imaging and guidance of intrauterine surgical procedures. Study design Forty-five patients who underwent intrauterine surgical interventions were evaluated. Forty of these patients had pregnancy terminations. Three patients had curettage for early pregnancy complications. One patient had a polyp removed, and one patient underwent hysteroscopic submucous myomectomy. Five attending physicians performed 26 procedures. Four residents in training performed 19 procedures. All operators were instructed in the assembly and use of the device before their first procedure. Evaluation of the device was done by means of a detailed questionnaire. Results The procedures were completed successfully and without complications. The time that was involved for the various components of the surgical procedures was recorded; 83% to 90% of the time the operators felt that the technique increased safety and accuracy for the parameters that were evaluated. They required fewer intrauterine instrument manipulations; in 85% of the cases, they could detect the exact end point of the procedure more accurately. In 12% of cases, the operators felt that the device interfered with the performance of the procedure. Conclusions The transvaginal ultrasound-assisted gynecological surgery system provided high-resolution images of the cervical canal and the uterine cavity during all stages of the procedure and provided improved indication of the procedureʹs end point. The increased safety and accuracy that was reported by most users was encouraging. The transvaginal ultrasound-assisted gynecologic surgery system appears to provide an enhanced alternative to transabdominal ultrasound guidance for intrauterine surgical procedures.
Keywords :
pregnancy termination , transvaginalultrasound , Ultrasound guidance , intrauterine procedures
Journal title :
American Journal of Obstetrics and Gynecology
Serial Year :
2003
Journal title :
American Journal of Obstetrics and Gynecology
Record number :
643709
Link To Document :
بازگشت