Title of article :
Erosive Pressure Dermatitis Associated with Cardiac Pacemaker
Author/Authors :
Hayedeh Ghaninejadi، نويسنده , , Soheil Fateh، نويسنده , , Roghie Shamsoddini، نويسنده , , Farshad Farshidfar، نويسنده ,
Issue Information :
فصلنامه با شماره پیاپی سال 2009
Pages :
2
From page :
25
To page :
26
Abstract :
Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor for both pacemakers and changing the type of pacemaker is not important in some cases.
Keywords :
Pacemaker , Erosion , pacemaker dermatitis